RF Interconnects for Energy Systems and Industrial Sensors

Energy infrastructure is installed once and expected to report for thirty years. Substation telemetry, distributed sensing and condition monitoring all sit outdoors, unattended, in weather and electrical noise that would disable a laboratory instrument in an afternoon.

Substation
IP67
Telemetry
Condition Monitoring
30-Year Life
IP67
Ingress Rating
-40° to +125°
Temperature
DC–18 GHz
Coverage
Design Notes

Installed Once, Reporting for Decades

Five factors that decide whether an outdoor sensor link is still working in year twenty.

01
Water Ingress
Every temperature cycle breathes air, and therefore moisture, through any imperfect seal. Sealing at the interface rather than at the enclosure is what stops it.
02
Electrical Environment
Substations are electrically violent places. Switching transients and corona put energy across a very wide spectrum, and screening is what keeps it out of the signal.
03
UV and Ozone
Jacket materials age in sunlight and in the ozone a high-voltage environment produces. The cable often fails before the connector does.
04
No Maintenance Window
Taking an asset out of service to fix a sensor is expensive, so it usually does not happen. The interconnect has to outlast the interest in fixing it.
05
Retrofit Constraints
Most installations are on existing plant. Interfaces have to work with what is already there, not with an ideal design.
Reference Data

Typical Installation Requirements

Utility and plant specifications govern. These are representative.

ParameterTypical RequirementRelevant SeriesNote
Ingress protectionIP67 matedSealed N-Type, TNCSealed at the interface
Temperature-40 °C to +125 °CIndustrial seriesOutdoor, unshaded
Screening≥ 90 dBDouble-braid assembliesSwitching transients
UV resistancePer jacket specificationUV-stable jacketsDirect sunlight
Salt sprayMIL-STD-202 Method 101Passivated bodiesCoastal installations
Service life20–30 yearsIndustrial seriesNo maintenance window
Our Role

What We Supply for Energy Installations

01
Sealed Outdoor Interfaces
N-type and TNC bodies sealed at the interface, so the thermal breathing cycle cannot draw moisture into the joint.
02
Assemblies for Retrofit
Built to the lengths and interfaces the existing plant actually has, so installation does not require rework on site.
03
Documented for Handover
Material certificates and measured data in the form asset owners expect at commissioning.
Industrial Engineering Support

Specifying an Outdoor Sensor Link?

Send us the installation environment, the run lengths and the existing interfaces, and our engineers will propose the interconnect.